Validation of the Ants-TRACE code system with VVER-1000 coolant transient benchmarks
Year of publication
2023
Authors
Lauranto, Unna; Komu, Rebekka; Rintala, Antti; Valtavirta, Ville
Abstract
<p>The objective of this paper is to start the validation of the coupled code system of the nodal neutronics solver Ants and the system code TRACE. The process consists of two exercises of well-known VVER-1000 coolant transient benchmarks: a core-vessel simulation of a main steam line break transient of the V1000CT-2 benchmark and a full plant simulation of a main coolant pump trip of the Kalinin-3 benchmark. The Ants-TRACE results are compared against other code solutions in the V1000CT-2 benchmark and measurement data in the Kalinin-3 benchmark. The results show good agreement in both benchmarks, with the deviations ranging mostly within the measurement error or the range of deviations of other published solutions. The results confirm the correct implementation of the coupling and successful modeling of relevant phenomena in coolant transient events in a VVER-1000 reactor.</p>
Show moreOrganizations and authors
Publication type
Publication format
Article
Parent publication type
Journal
Article type
Original article
Audience
ScientificPeer-reviewed
Peer-ReviewedMINEDU's publication type classification code
A1 Journal article (refereed), original researchPublication channel information
Journal
Volume
190
Article number
109879
ISSN
Publication forum
Publication forum level
1
Open access
Open access in the publisher’s service
Yes
Open access of publication channel
Partially open publication channel
License of the publisher’s version
CC BY
Self-archived
No
Other information
Fields of science
Physical sciences
Keywords
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Language
English
International co-publication
No
Co-publication with a company
No
DOI
10.1016/j.anucene.2023.109879
The publication is included in the Ministry of Education and Culture’s Publication data collection
Yes