undefined

Monitoring of indoor air quality at a large sailing cruise ship to assess ventilation performance and disease transmission risk

Year of publication

2025

Authors

Cheung, Ho Yin Wickson; Kumar, Prashant; Hama, Sarkawt; Emygdio, Ana Paula Mendes; Wei, Yingyue; Anagnostopoulos, Lemonia; Ewer, John; Ferracci, Valerio; Galea, Edwin R.; Grandison, Angus; Hadjichristodoulou, Christos; Jia, Fuchen; Lepore, Pierfrancesco; Morawska, Lidia; Mouchtouri, Varvara A.; Siilin, Niko; Wang, Zhaozhi; HEALTHY SAILING project
Show more

Abstract

<p>Large passenger ships are characterised as enclosed and crowded indoor spaces with frequent interactions between travellers, providing conditions that facilitate disease transmission. This study aims to provide an indoor ship CO<sub>2</sub> dataset for inferring thermal comfort, ventilation and infectious disease transmission risk evaluation. Indoor air quality (IAQ) monitoring was conducted in nine environments (three cabins, buffet, gym, bar, restaurant, pub and theatre), on board a cruise ship voyaging across the UK and EU, with the study conducted in the framework of the EU HEALTHY SAILING project. CO<sub>2</sub> concentrations, temperature and relative humidity (RH) were simultaneously monitored to investigate thermal characteristics and effectiveness of ventilation performance. Results show a slightly higher RH of 68.2 ± 5.3 % aboard compared to ASHRAE and ISO recommended targets, with temperature recorded at 22.3 ± 1.4 °C. Generally, good IAQ (&lt;1000 ppm) was measured with CO<sub>2</sub> mainly varying between 400 and 1200 ppm. The estimated air change rates (ACH) and ventilation rates (VR) implied sufficient ventilation was provided in most locations, and the theatre (VR: 86 L s<sup>−1</sup> person<sup>−1</sup>) and cabins (VR: &gt;20 L s<sup>−1</sup> person<sup>−1</sup>) were highly over-ventilated. Dining areas including the pub and restaurant recorded high CO<sub>2</sub> concentrations (&gt;2000 ppm) potentially due to higher footfall (0.6 person m<sup>−2</sup> and 0.4 person m<sup>−2</sup>) and limited ACH (2.3 h<sup>−1</sup> and 0.8 h<sup>−1</sup>), indicating a potential risk of infection; these areas should be prioritised for improvement. The IAQ and probability of infection indicate there is an opportunity for energy saving by lowering hotel load for the theatre and cabins and achieving the minimum acceptable VR (10 L s<sup>−1</sup> person<sup>−1</sup>) for occupants' comfort and disease control. Our study produced a first-time dataset from a sailing cruise ship's ventilated areas and provided evidence that can inform guidelines about the optimisation of ventilation operations in large passenger ships, contributing to respiratory health, infection control and energy efficiency aboard.</p>
Show more

Organizations and authors

Publication type

Publication format

Article

Parent publication type

Journal

Article type

Original article

Audience

Scientific

Peer-reviewed

Peer-Reviewed

MINEDU's publication type classification code

A1 Journal article (refereed), original research

Publication channel information

Volume

962

Article number

178286

​Publication forum

66887

​Publication forum level

2

Open access

Open access in the publisher’s service

Yes

Open access of publication channel

Partially open publication channel

License of the publisher’s version

CC BY

Self-archived

No

Other information

Fields of science

Environmental engineering

Keywords

[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]

Language

English

International co-publication

Yes

Co-publication with a company

Yes

DOI

10.1016/j.scitotenv.2024.178286

The publication is included in the Ministry of Education and Culture’s Publication data collection

Yes