Validity of the Wrist-Worn Polar Vantage V2 to Measure Heart Rate and Heart Rate Variability at Rest
Year of publication
2022
Authors
Nuuttila, Olli-Pekka; Korhonen, Elisa; Laukkanen, Jari; Kyröläinen, Heikki
Abstract
Heart rate (HR) and heart rate variability (HRV) can be monitored with wearable devices throughout the day. Resting HRV in particular, reflecting cardiac parasympathetic activity, has been proposed to be a useful marker in the monitoring of health and recovery from training. This study examined the validity of the wrist-based photoplethysmography (PPG) method to measure HR and HRV at rest. Recreationally endurance-trained participants recorded pulse-to-pulse (PP) and RR intervals simultaneously with a PPG-based watch and reference heart rate sensor (HRS) at a laboratory in a supine position (n = 39; 5-min recording) and at home during sleep (n = 29; 4-h recording). In addition, analyses were performed from pooled laboratory data (n = 11340 PP and RR intervals). Differences and correlations were analyzed between the HRS- and PPG-derived HR and LnRMSSD (the natural logarithm of the root mean square of successive differences). A very good agreement was found between pooled PP and RR intervals with a mean bias of 0.17 ms and a correlation coefficient of 0.993 (p < 0.001). In the laboratory, HR did not differ between the devices (mean bias 0.0 bpm), but PPG slightly underestimated the nocturnal recordings (bias −0.7 bpm, p < 0.001). PPG overestimated LnRMSSD both in the laboratory (bias 0.20 ms, p < 0.001) and nocturnal recordings (bias 0.17 ms, p < 0.001). However, very strong intraclass correlations in the nocturnal recordings were found between the devices (HR: 0.998, p < 0.001; LnRMSSD: 0.931, p < 0.001). In conclusion, PPG was able to measure HR and HRV with adequate accuracy in recreational athletes. However, when strict absolute values are of importance, systematic overestimation, which seemed to especially concern participants with low LnRMSSD, should be acknowledged.
Show moreOrganizations and authors
University of Eastern Finland
Laukkanen Jari Antero
Publication type
Publication format
Article
Parent publication type
Journal
Article type
Original article
Audience
ScientificPeer-reviewed
Peer-ReviewedMINEDU's publication type classification code
A1 Journal article (refereed), original researchPublication channel information
Open access
Open access in the publisher’s service
Yes
Open access of publication channel
Fully open publication channel
Self-archived
Yes
Article processing fee (EUR)
1983
Year of payment for the open publication fee
2021
Other information
Fields of science
Sport and fitness sciences; General medicine, internal medicine and other clinical medicine; Health care science
Keywords
[object Object],[object Object],[object Object],[object Object]
Publication country
Switzerland
Internationality of the publisher
International
Language
English
International co-publication
No
Co-publication with a company
No
DOI
10.3390/s22010137
The publication is included in the Ministry of Education and Culture’s Publication data collection
Yes