undefined

Feasibility and repeatability of MEG-compatible patellar-tendon stimulator for eliciting knee-joint proprioceptive cortical responses

Year of publication

2027

Authors

Li, Feiyue; Byman, Anni; Chen, Junru; Mujunen, Toni; Piitulainen, Harri

Abstract

Background Cortical processing of proprioceptive-dominant afference arising from the knee joint is largely unknown. Magnetoencephalography (MEG) can be used to quantify the cortical processing of the proprioceptive afference, but MEG-compatible and well-controlled stimulation of the knee joint is technically challenging, and thus has received less attention. New method We introduced a novel MEG-compatible stimulator that delivers controlled patellar tendon taps and elicits proprioceptive-dominant afferent input to the cortex in the knee joint. The stimulus intensity is adjustable, allowing graded activation of proprioceptive input and, when required, elicitation of the patellar-tendon reflex. Results The novel stimulator elicited clear muscular and cortical responses in both intensity conditions. Cortical responses demonstrated moderate to excellent intersession reliability for peak evoked field amplitude (ICC: 0.69–0.96), beta suppression (0.89–0.90) and beta rebound (0.96–0.97). Notably, beta suppression peaked more laterally than expected in both hemispheres. Peak EMG amplitudes in VL and VM muscles were reliable for both intensity conditions (ICC: 0.66–0.89), and stimulus kinematics remained consistent throughout measurements. Comparison with existing methods Previous robotic or motor-driven devices have been used to evoke cortical responses to knee-joint proprioceptive stimulation, but mechanical coupling across adjacent joints may limit knee-specific input. The present stimulator provides a mechanically simple and MEG-compatible tool that targets proprioceptive-dominant afferents of the knee joint more directly, reduces distal joint involvement. Conclusion The novel stimulator is a feasible and repeatable tool for studying cortical processing of proprioceptive afference from the knee joint using MEG.
Show more

Organizations and authors

University of Jyväskylä

Byman-Vornanen Anni

Li Feiyue

Piitulainen Harri Orcid -palvelun logo

Chen Junru Orcid -palvelun logo

Mujunen Toni

University of Helsinki

Byman Anni

Piitulainen Harri

Helsinki University Hospital

Byman Anni

Piitulainen Harri

Publication type

Publication format

Article

Report

No

Parent publication type

Journal

Article type

Original article

Audience

Scientific

Peer-reviewed

Peer-Reviewed

MINEDU's publication type classification code

A1 Journal article (refereed), original research

Publication channel information

Parent publication name

Journal of Neuroscience Methods

Publisher

Elsevier

Volume

437

Article number

110915

​Publication forum

61155

​Publication forum level

1

Open access

Open access in the publisher’s service

Yes

Open access of publication channel

Partially open publication channel

License of the publisher’s version

CC BY NC ND

Self-archived

Yes

License of the self-archived publication

CC BY NC ND

Other information

Fields of science

Sport and fitness sciences; Neurosciences

Identified topic

[object Object]

Publication country

Netherlands

Internationality of the publisher

International

Language

English

International co-publication

Yes

Co-publication with a company

No

DOI

10.1016/j.jneumeth.2026.110915

The publication is included in the Ministry of Education and Culture’s Publication data collection

Yes